Ruthenium bath extra black 5gr/l
RU5BLACK-X is an extra black ruthenium plating electrolyte which deposits a glossy layer of ruthenium metal in ultrablack color.
instructions for use
safety data sheet
Use : ready to use
Temperature : 50-70°C, optimal : 60°C
Current : 1,8-2,2 Volt, optimal : 2 Volt
Time : 1-6 min, optimal : 4 min
Anode : platinized titanium
Volume : 1000 ml
Ruthenium : 5 gr
Current daily rate.
LEGOR
safety data sheet